Table 105: Event Code 586
Message:
Invalid primitive sequence received for current link state.
Severity:
Major.
Explanation:
An attached OSI server recognized either a link reset (LR) or a link-reset response
(LRR) sequence while in the wait-for-online sequence (OLS) state.
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
on page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.