HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 90

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
Does the Status field display a Failed message for the CTP?
NO
Additional analysis is not described in this MAP. Go to
on page 32. If this is the second time at this step, contact the next level of support.
Exit MAP.
16
Does a blinking red and yellow diamond (failed FRU indicator) appear to overlay
a combined fan module and power supply graphic at the Hardware View?
NO
17
At the Hardware View, does a grey square appear at the alert panel, a No Link
status appear at the Edge Switch Status table, and graphical FRUs appear
uninstalled?
YES
The grey square indicates the HAFM appliance cannot communicate with the
switch because:
Go to
and an Ethernet link or AC power distribution failure is ruled out, a CTP card
failure is indicated. Replace the switch. Exit MAP.
page 202page 182
92
YES
A CTP card failure is indicated. Replace the switch.
Exit MAP.
YES
A fan module failure is indicated. Go to
NO
A green circle appears at the alert panel and the switch appears
operational. Exit MAP.
The switch-to-HAFM appliance Ethernet link failed.
AC power distribution in the switch failed, or AC power was disconnected.
The switch CTP card failed.
"MAP 0000: Start
MAP" on page 32. If this is the second time at this step
"MAP 0000: Start
step
6.
Edge Switch 2/24 Service Manual
MAP"