Table 45: Event Code 081 (Continued)
Event Data:
The first byte of event data (byte 0) specifies the port number. The fifth byte (byte 4)
specifies the isolation reason as follows:
1 = Unknown–Isolation reason is unknown, but probably caused by failure of a
device attached to the switch through an E_Port connection. Fault isolate the failed
device or contact support personnel to report the problem.
2 = ISL connection not allowed–The port connection conflicts with the configured
port type. Change the port type to F_Port if the port is cabled to a device, or E_Port
if the port is cabled to a fabric element to form an ISL.
3 = Incompatible switch–The switch returned a Process ELP Reject–Unable
to Process reason code because the attached fabric element is not compatible.
Set the switch operating mode to Homogeneous Fabric 1.0 if connected to an HP
product. Set the switch operating mode to Open Fabric 1.0 if connected to an
open-fabric compliant product manufactured by a different vendor.
4 = Incompatible switch–The switch returned a
Revision Level reason code because the attached fabric element is not
compatible. Set the switch operating mode to Homogeneous Fabric 1.0 if
connected to an HP product. Set the switch operating mode to Open Fabric 1.0 if
connected to an open-fabric compliant product manufactured by a different
vendor.
5 = Loopback plug connected–A loopback plug is connected to the port with no
diagnostic test running. Remove the loopback plug.
6 = N_Port connection not allowed–The switch is connected to a fabric element
through a port configured as an F_Port. Change the port type to E_Port.
7 = Non-HP switch at other end–The attached fabric element is not an HP product.
Set the switch operating mode to Open Fabric 1.0 if connected to an open-fabric
compliant product manufactured by a different vendor.
A = Unauthorized port binding WWN–The device WWN or nickname used to
configure port binding for this port is not valid. Reconfigure the port with the WWN
or nickname authorized for the attached device.