Event Codes

CTP Card Events (400 through 499)

Table 74: Event Code 400
Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as
indicated by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure
is indicated, replace the power supply assembly. Perform the data collection
procedure and return the backup disk and faulty FRU to Hewlett-Packard support
personnel.
Event Data:
Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply
assembly.
Byte 1 = FRU slot number.
Distribution:
Switch
EWS
Event
Log
Table 75: Event Code 410
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can
occur automatically after a firmware fault (event code 411), or be user-initiated.
Event data indicates the type of reset.
Action:
No action required.
Event Data:
Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution:
Switch
EWS
Event
Log
280
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Edge Switch 2/24 Service Manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents