HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 247

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Table 50: Event Code 142
Message:
Low BB_Credit detected on an ISL.
Severity:
Informational.
Explanation
Open Trunking firmware detected an ISL with no transmission BB_Credit for a period
:
of time that exceeded the configured low BB_Credit threshold. This indicates
downstream fabric congestion.
Action:
No action is required for an isolated event or if the reporting ISL approaches 100%
throughput. If this event persists, relieve the low BB_Credit condition by adding
parallel ISLs, increasing the ISL link speed, or moving device connections to a
less-congested region of the fabric.
Event Data:
Byte 0 = Port number reporting low BB_Credit.
Distribution
Switch
:
EWS
Event Log
Table 51: Event Code:143
Message:
Low BB_Credit relieved on an ISL.
Severity:
Informational.
Explanati
Open Trunking firmware detected an ISL with no transmission BB_Credit for a period of
on:
time that previously exceeded the configured low BB_Credit threshold. The low-credit
condition is now relieved.
Action:
No action required.
Event
Byte 0 = Port number reporting low BB_Credit relieved.
Data:
Distributi
Switch
on:
EWS
Event Log
Edge Switch 2/24 Service Manual
HAFM Appliance
System
Event Log
Error LED
HAFM Appliance
System
Event Log
Error LED
E-Mail
Call-Home
E-Mail
Call-Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident