Table 64: Event Code 302
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Three cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of the
power supply assembly (or assemblies) associated with the failed fans.
Action:
Replace the power supply assembly (or assemblies) containing the indicated fan
modules.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution:
Switch
EWS
Event
Log
Table 65: Event Code 303
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Four cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of both
power supply assemblies.
Action:
Replace the failed fans. Replace both power supply assemblies.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/24 Service Manual
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
275

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents