Port Events (500 through 599)

Table 90: Event Code 506
Message:
Fibre Channel port failure.
Severity:
Major.
Explanation:
A Fibre channel port failed. The amber LED corresponding to the port illuminates to
indicate the failure. Other ports remain operational if their LEDs are extinguished.
Action:
Perform the data collection procedure and return the backup disk to
Hewlett-Packard support personnel.
Perform a switch reset. If the problem persists, replace the switch.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific.
Byte 16 = connector type.
Bytes 17 and 18 = transmitter technology.
Byte 19 = distance capabilities.
Byte 20 = supported transmission media.
Byte 21 and 22 = speed capability and configuration.