Table 92: Event Code 508 (Continued)
Distribution:
Switch
EWS
Event
Log
Table 93: Event Code 510
Message:
SFP optical transceiver hot-insertion initiated.
Severity:
Informational.
Explanation:
Installation of a small form factor pluggable (SFP) optical transceiver was initiated
with the switch powered on and operational. The event indicates that operational
firmware detected the presence of the transceiver.
Action:
No action required.
Event Data:
Byte 0 = port number (00 through 23).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Switch
EWS
Event
Log
Table 94: Event Code 512
Message:
SFP optical transceiver nonfatal error.
Severity:
Minor.
Explanation:
Switch firmware detected an SFP optical transceiver non-fatal error.
Action:
Replace the failed transceiver with a functional transceiver of the same type.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/24 Service Manual
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
291

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents