Event Codes
Table 40: Event Code 071 (Continued)
Event Data
4 = Build fabric protocol error. A protocol error was detected during incorporation
(continued):
of the switch into the fabric. Disconnect the E_Port link, reconnect the link, and IPL
the switch. If the condition persists, perform the data collection procedure and
return the backup disk to Hewlett-Packard support personnel.
5 = No principal switch. No Director or Edge Switch in the fabric can become the
principal switch. Modify the switch priority to any value other than 255.
6 = No response from attached switch (hello timeout). The switch periodically
verifies operation of attached fabric elements (Director or Edge Switch). The switch
E_Port (at the operational switch) times out and segments if the attached device
does not respond. Check the status of the attached Director or Edge Switch. If the
condition persists, perform the data collection procedure (at the attached device)
and return the backup disk to Hewlett-Packard support personnel.
Distribution:
Switch
EWS
Event
Log
Table 41: Event Code 072
Message:
E_Port connected to unsupported switch.
Severity:
Informational.
Explanation:
The switch is attached (through an ISL) to an incompatible fabric element (Director
or Edge Switch).
Action:
Disconnect the ISL.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
258
Event Code: 071 (continued)
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Edge Switch 2/24 Service Manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents