Table 22: Port Operational States (Continued)
Port
Blue/Green
State
No Light
Off
Inactive
On
Not Installed
Off
Not
Off
Operational
Port Failure
Off
Segmented
On
E_Port
Testing
Off
On
Edge Switch 2/24 Service Manual
Amber
LED
LED
Off
Off
Off
Off
On
Off
Blinking
Blinking
Alert
Symbol
None
No signal (light) is received at the switch
port. This is a normal condition when
there is no cable attached to the port or
when the attached device is powered
off.
Yellow
The port is inactive. The reason displays
Triangle
in the Reason field at the Port
Properties dialog box.
None
An optical transceiver is not installed in
the switch port.
Yellow
The port is receiving the not operational
Triangle
sequence (NOS) from an attached
device.
Red and
The port failed and requires service.
Yellow
Blinking
Diamond
Yellow
The E_Port is segmented, preventing two
Triangle
connected switches from joining and
forming a multiswitch fabric.The reason
displays in the Reason field of the Port
Properties dialog box.
Yellow
The port is performing an internal
Triangle
loopback test.
Yellow
The port is performing an external
Triangle
loopback test.