HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 219

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Table 30:
Could not write firmware
to flash.
CUP name and port
name are identical.
Date entered is invalid.
Device applications
should be terminated
before starting
diagnostics. Press NEXT
to continue.
[device WWN] cannot
be removed from the
Switch Membership List
while participating in
Switch Binding. The
device must be isolated
from the switch, or
Switch Binding
deactivated before it can
be removed.
Disabling Insistent
Domain ID will disable
Fabric Binding. Do you
want to continue?
Disabling Switch Binding
will disable Enterprise
Fabric Mode. Do you
want to continue?
Do you want to continue
with IPL?
Edge Switch 2/24 Service Manual
Element Manager Messages (Continued)
Edge Switch 2/24
Message
Firmware could not be
written to flash memory.
Within the address
configuration, one or
more of the port names
are the same as the CUP
name.
Date entered incorrectly.
Device application is not
terminated.
User attempted to
remove a device WWN
from the Switch
Membership List
(SANtegrity Binding
feature) while Switch
Binding is enabled.
Fabric Binding is
enabled through the
HAFM and user
attempted to disable
Insistent Domain ID in
the Configure Switch
Parameters dialog box.
User attempting to
disable Switch Binding
through the Switch
Binding State Change
dialog box, but
Enterprise Fabric Mode
is enabled
Requesting confirmation
to proceed with an IPL.
Description
Messages
Action
Try again. If problem
persists, contact support
personnel.
Make sure all names are
unique for the ports and
CUP name.
Verify that the number of
days in the month is valid.
Terminate device
application before running
port diagnostics.
Remove the device from the
switch by blocking the port,
setting the switch offline, or
disabling Switch Binding
through the Switch Binding
Change State dialog box
before removing devices
form the Switch
Membership List.
Click Yes if you want to
continue and disable
Fabric Binding.
Disable Enterprise Fabric
Mode using the Enterprise
Fabric Mode dialog box in
the HAFM before disabling
Switch Binding.
Click Yes to confirm the IPL
or Cancel to cancel the
operation.
235

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents