Setting The Cpu Threshold Notification Types And Values; Setting The Agent Contact And Location Information - Cisco WS-CBS3032-DEL Software Configuration Manual

Software guide
Table of Contents

Advertisement

Configuring SNMP

Setting the CPU Threshold Notification Types and Values

Beginning in privileged EXEC mode, follow these steps to set the CPU threshold notification types and
values:
Command
Step 1
configure terminal
Step 2
process cpu threshold type {total | process
| interrupt} rising percentage interval
seconds [falling fall-percentage interval
seconds]
Step 3
end
Step 4
show running-config
Step 5
copy running-config startup-config

Setting the Agent Contact and Location Information

Beginning in privileged EXEC mode, follow these steps to set the system contact and location of the
SNMP agent so that these descriptions can be accessed through the configuration file:
Command
Step 1
configure terminal
Step 2
snmp-server contact text
Step 3
snmp-server location text
Step 4
end
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide
33-16
Purpose
Enter global configuration mode.
Set the CPU threshold notification types and values:
total—set the notification type to total CPU utilization.
process—set the notification type to CPU process utilization.
interrupt—set the notification type to CPU interrupt utilization.
rising percentage—the percentage (1 to 100) of CPU resources
that, when exceeded for the configured interval, sends a CPU
threshold notification.
interval seconds—the duration of the CPU threshold violation in
seconds (5 to 86400) that, when met, sends a CPU threshold
notification.
falling fall-percentage—the percentage (1 to 100) of CPU
resources that, when usage falls below this level for the
configured interval, sends a CPU threshold notification.
This value must be equal to or less than the rising percentage
value. If not specified, the falling fall-percentage value is the
same as the rising percentage value.
Return to privileged EXEC mode.
Verify your entries.
(Optional) Save your entries in the configuration file.
Purpose
Enter global configuration mode.
Set the system contact string.
For example:
snmp-server contact Dial System Operator at beeper 21555.
Set the system location string.
For example:
snmp-server location Building 3/Room 222
Return to privileged EXEC mode.
Chapter 33
Configuring SNMP
OL-13270-06