Displaying Obfl Information - Cisco WS-CBS3032-DEL Software Configuration Manual

Software guide
Table of Contents

Advertisement

Using On-Board Failure Logging
We recommend that you do not disable OBFL and that you do not remove the data stored in the flash
Caution
memory.
To disable OBFL, use the no hw-module module [switch-number] logging onboard [message level]
global configuration command.
To clear all the OBFL data in the flash memory except for the uptime and CLI command information,
use the clear logging onboard privileged EXEC command.
In a switch stack, you can enable OBFL on a standalone switch or on all stack members by using the
hw-module module logging onboard [message level level] global configuration command.
For more information about the commands in this section, see the command reference for this release.

Displaying OBFL Information

To display the OBFL information, use one or more of the privileged EXEC commands in
Table 48-4
Commands for Displaying OBFL Information
Command
show logging onboard [module
[switch-number]] clilog
show logging onboard [module
[switch-number]] environment
show logging onboard [module
[switch-number]] message
show logging onboard [module
[switch-number]] poe
show logging onboard [module
[switch-number]] temperature
show logging onboard [module
[switch-number]] uptime
show logging onboard [module
[switch-number]] voltage
For more information about using the commands in
command reference for this release.
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide
48-24
Purpose
Displays the OBFL CLI commands that were entered on a standalone
switch or the specified stack members.
Display the UDI information for a standalone switch or the specified
stack members and for all the connected FRU devices: the PID, the VID,
and the serial number.
Display the hardware-related messages generated by a standalone switch
or the specified stack members.
Display the power consumption of PoE ports on a standalone switch or
the specified stack members.
Display the temperature of a standalone switch or the specified switch
stack members.
Display the time when a standalone switch or the specified stack members
start, the reason the standalone switch or specified stack members restart,
and the length of time that the standalone switch or specified stack
members have been running since they last restarted.
Display the system voltages of a standalone switch or the specified stack
members.
Table 48-4
Chapter 48
Troubleshooting
and for examples of OBFL data, see the
Table