ITech IT6600C Series User Manual page 98

Bidirectional programmable dc power supply

Advertisement

U
U
2
U
1
Parameter
U
1
U
2
t
f
t
r
t
1
cycles
How to Use
The following is an example of how to use this function by recalling the LV124
standard regulation E-01 test.
1.
Click Vehicle on the Menu screen to enter the vehicle test screen.
1) Press the up/down key to move the cursor to the Standards function
2) Press the up/down key to move the cursor to the Testings function
3) Press the up/down key to move the cursor to the Testcase function
4) Set U
2.
Press [Run] in the Vehicle function interface.
1Cycle
Description
11.8V
15V
>=300ms
2s
10
setting and press the [Enter] key to confirm. Rotate the knob to select
LV124 and press the [Enter] key to confirm.
setting and press the [Enter] key to confirm. Rotate the knob to select
E-01 and press the [Enter] key to confirm.
setting and press the [Enter] key to confirm. Rotate the knob to select
Standard and press the [Enter] key to confirm.
= 17V, U
= 13.5V, t
max
min
Copyright ©ITECH Electronic Co., Ltd.
<10ms, t
= 3600s and t
r
1
Power Supply Function
< 10ms.
f
89