Output
Resistance
Onoff Delay
5.3 Key Lock Function
Press [Shift] + [2] (Lock) button to set the key lock state. If keyboard has been
locked, the indicator light
keyboard are locked, all buttons can't be used except Local key Press [Shift] +
[2] (Lock) once again will relieve key lock function.
5.4 Switching Local/Remote Mode
You can press the [Shift] +[3] (Local) button to change the DC source from
remote to local operation.
After you power on the DC source, it defaults in local mode, all buttons are
enabled. While in remote mode, most buttons are disabled except [Shift] +[3]
(Local) keys. You can switch Local/Remote mode via PC. In addition, the mode
modification will not affect the output parameters.
5.5 Save and Recall Operations
The power system can save up to 100 common parameters in nonvolatile
memory (No. 1 to No. 100) for user to recall conveniently.
The saved parameters include:
Power supply mode
Present output parameters
Config menu settings
Save Operation
The save operation procedures are as follows:
1.
Press the composite keys [Shift]+[4](Save) to enter the parameter save
interface.
2.
Select the storage location. up to 100 position can be select.
Frequency
Set the internal resistance of the power supply. (This item is only
displayed when CV is prioritized.)
On Delay
Off Delay
will display on the LCD. In addition, when
Copyright ©ITECH Electronic Co., Ltd.
Set the AC frequency. (This item is only
displayed when in DCAC output mode.)
Set the delay time to turn on the output.
Offset: Set the output delay offset time.
Set the delay time to turn off the output.
System-Related Functions
137