COMSPHERE 3600 Series Data Service Units

Digital Test

The Digital Test (DT) checks the functionality of a pair
of DSUs or DBMs and the data circuit between them.
The Digital Test uses the local DSU's test pattern
generator. In a multipoint network where only a control
DSU can originate a Digital Test, tributary DSUs not
involved in the test are placed in Test mode for the
duration of the test.
Digital test is not available when:
In remote mode, or
Alternate Port 1 has NetIntf set to forced on (Forc)
with the DSU in Backup mode, or
LPDA-2 configuration option is enabled
The local DSU transmits the test pattern over the
network to the remote DSU, which is placed in Remote
Digital Loopback (RL); the user inputs the length of time.
During the test, the TXD, RXD, and RTS LEDs show
the states of the leads at the DTE interface. At the
conclusion of the test, the local DSU releases the remote
DSU from Digital Loopback.
To review the results of the DT test, press
Display (Displ). When using the front panel, press the
key to scroll through the results shown in Table 3-3.
The Clear (Clr) selection clears the test results and resets
the counter to zero.
Table 3-3
Digital Test Results
Results
Information Displayed
Time:
Running test timer.
Tot
Running count of bits in error. MAX appears
Error:
when the error count reaches about 65000.
Err
Running count of errored seconds: An
Secs:
errored second is at least one error detected
during a 1-second time period.
Run on:
Port number appears if this test was not run
port nn
on an aggregate data path.
When the test is complete:
The top line display changes from Active to Final.
The second line changes from Please wait . . . to
either Command Complete or Command Failed.
3-12

End-to-End Test

The End-to-End (EE) test analyzes a control and a
tributary DSU or DBM and the network circuit between
them in both directions independently. Packets of data are
transmitted between DSUs or DBMs.
The test determines the direction of the data
transmission problem if the circuit is the cause. If an
End-to-End test is run, the in-band diagnostics are
disrupted. EE does not appear when in Remote mode.
To review the results of the EE test, press
Display (Displ). When using the front panel, press the
key to scroll through the results shown in Table 3-4.
The Clear (Clr) selection clears the test results and resets
the timer to zero.
Results
Time:
and select
Tot Block:
Rx Blk Err: Local &
Tx Blk Err:
Rx
TimOuts:
*
Local refers to the test initiator.
When the test is over:
The top line display changes from Active to Final.
The second line changes from Please wait . . . to
either Command Complete or Command Failed.
December 1996
Table 3-4
End-to-End Test Results
Reported
Information Displayed
*
By
Local &
Running test timer.
remote
DSU/DBM
Local &
Number of blocks completed.
remote
DSU/DBM
Number of incoming blocks
remote
with errors detected,
DSU/DBM
indicating an error in the
incoming transmission path.
Local &
Number of blocks with errors
remote
detected at the remote DSU,
DSU/DBM
indicating an error in the
outgoing transmission path.
Local
Number of blocks that were
DSU/DBM
not received or acknowledged
only
by the remote DSU or DBM.
and select
3610-A2-GB46-60