Remove The Fan - HPE ProLiant DL325 Gen11 User Manual

Hide thumbs Also See for ProLiant DL325 Gen11:
Table of Contents

Advertisement

Remove the fan

Remove the fan
About this task
About this task
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
CAUTION:
either a component or a blank.
IMPORTANT:
IMPORTANT:
The fan setup can either be standard, single-rotor fans or high performance, dual-rotor fans. Do not mix fan types in the
same server.
CAUTION:
CAUTION:
To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or
replacement procedure. Improper grounding can cause electrostatic discharge.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Remove the server from the rack.
5. Place the server on a flat, level work surface.
6. Remove the access panel .
7. Remove the air baffle .
8. Remove a standard or high performance fan.
HPE ProLiant DL325 Gen11 Server User Guide