2. Remove the ground wire screw (callout 1), and then remove the positive return wire and negative input wire screws (callout 2).
3. Attach the ground wire (green and yellow) to the DC power supply (callout 1) and tighten the screw and washer with 1.47 N-m (13 lbf-
in) torque (callout 2).
4. Install the positive return wire (red):
a. Insert the positive return wire (red) into the RTN slot on the DC power supply (callout 1).
b. Tighten the screw with 0.98 N-m (8.68 lbf-in) torque (callout 2).