Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
Storage controller backup power cable (ships with the storage controller)
Energy pack extension power cable (P56659-B21)
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Remove the server from the rack.
5. Place the server on a flat, level work surface.
6. Remove the access panel .
7. Remove the middle cover .
8. Secure the energy pack in the retention latch located on the rear side of the drive cage.
9. Connect the energy pack extension power cable to the system board and energy pack cable .
10. Connect the storage backup power cable .
11. Install the access panel .
12. Install the server into the rack.
13. Connect all peripheral cables to the server.
14. Connect the power cords:
a. Connect each power cord to the server.
b. Connect each power cord to the power source.
15. Power up the server.
Results
Results
The installation is complete.