1. Select the Enclosure Information tab.
2. In the Device Bays item, select the server.
3. From the Virtual Power menu, initiate a shutdown of applications and the OS:
◦
For a controlled shutdown, select Momentary Press.
For an emergency shutdown, select Press and Hold.
◦
Before proceeding, verify that the server blade is in standby mode by observing that the system power LED is amber.
Remove the server blade
CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade enclosure unless all
bays are populated with either a component or a blank.
Procedure
1. Identify the proper server blade.
2. Power down the server blade.
3. Remove the server blade.
4. Place the server blade on a flat, level work surface.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any
installation procedure. Improper grounding can cause electrostatic discharge.
Removal and replacement procedures
33