Power Down The Server; Remove The Server From The Rack - HPE ProLiant ML110 Gen10 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML110 Gen10:
Table of Contents

Advertisement

Procedure

Power down the server

Remove the server from the rack

NOTE: To install the server to the rack, reverse the removal procedure and place the server at the center of the tray
after installation.
Remove the access panel
Remove the front bezel
Power down the server
Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data
and programs.
IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the system.
To power down the server, use one of the following methods:
Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters standby mode.
Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS. If an
application stops responding, you can use this method to force a shutdown.
Use a virtual power button selection through iLO.
This method initiates a controlled remote shutdown of applications and the OS before the server enters standby
mode.
Before proceeding, verify that the server is in standby mode by observing that the system power LED is amber.
Remove the server from the rack
WARNING: This server is heavy. To reduce the risk of personal injury or damage to the equipment:
Observe local occupational health and safety requirements and guidelines for manual material handling.
Get help to lift and stabilize the product during installation or removal, especially when the product is not
fastened to the rails. Hewlett Packard Enterprise recommends that a minimum of two people are required for all
rack server installations. A third person may be required to help align the server if the server is installed higher
than chest level.
Use caution when installing the server in or removing the server from the rack; it is unstable when not fastened
to the rails.
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Removal and replacement procedures
31

Advertisement

Table of Contents
loading

Table of Contents