5. Install all the components removed from the system board.
6. Install the access panel.
7. Install the server into the rack.
8. Connect all peripheral cables to the server.
9. Connect the power cords:
a. Connect each power cord to the server.
b. Connect each power cord to the power source.
10. Power up the server.
11. Make sure all firmware, including option cards and embedded devices, is updated to the same versions to ensure that the latest drivers
are being used.
12. Re-enter the server serial number and product ID, and then configure the date and time settings .

Re-entering the server serial number and product ID

Re-entering the server serial number and product ID
About this task
About this task
After replacing the system board, re-enter the system serial number and product ID, and configure the date and time settings.
Procedure
Procedure
1. Access the UEFI System Utilities. During POST, press F9 F9.
2. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced
Service Options.
3. Select Serial Number, and then press Enter
The following warning appears:
The serial number is modified by qualified service personnel and must match the serial number
Enter.