Re-Entering The Server Serial Number And Product Id - HPE ProLiant DX4200 Gen10 Maintenance And Service Manual

Table of Contents

Advertisement

To replace the system board, do the following.
20. Insert the new system board into the tray.
21. Tighten the thumbscrew in the center of the system board.
22. Install all components removed from the failed system board.
Be sure to install the DIMMs and HPE Persistent Memory modules in the same DIMM slots as the failed system
board.
23. Review the persistent memory configuration of the system.
For more information, see Configuring the system for HPE Persistent Memory.
24. Do one of the following:
If HPE Persistent Memory modules are encrypted with local key management, either manually enter the HPE
Persistent Memory module passwords in the System Utilities or import the password file from the USB key.
If HPE Persistent Memory modules are encrypted with remote key management, enroll the system iLO in the key
management server to provide access to the data on the HPE Persistent Memory modules.
For more information, see the HPE Persistent Memory User Guide on the Hewlett Packard Enterprise website
(https://www.hpe.com/info/persistentmemory-docs).

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.
Procedure
1. During the server startup sequence, press the F9 key to access UEFI System Utilities.
2. Select the System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced System ROM
Options > Serial Number, and then press Enter.
3. Enter the serial number and press Enter. The following message appears: The serial number should
only be modified by qualified service personnel. This value should always
match the serial number located on the chassis.
Removal and replacement procedures
115