CAUTION:
CAUTION:
Before replacing a DIMM, backplane, expansion card, riser board, or other similar PCA components due to a perceived
hardware error, make sure first that the component is firmly seated in the slot.
When installing the replacement component:
Observe antistatic precautions.
Handle the PCA only along the edges.
Do not touch the components and connectors on the PCA.
Do not bend or flex the PCA.
Procedure
Procedure
1. Power down the server.
2. If installed, open the cable management arm .
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Disconnect all cables connected to the expansion card.
9. Remove the riser cage.
10. Remove the expansion card.
a. Remove the screw (callout 1).
b. Detach the expansion card from the riser (callout 2).
Results
Results
To replace the component, reverse the removal procedure.

Removing and replacing a fan blank

Removing and replacing a fan blank
About this task
About this task