Item
Item
Description
Description
1
Power On/Standby button and
system power LED
2
Health LED
3
NIC status LED
4
UID button/LED
When all LEDs flash simultaneously, a power fault has occurred. For more information, see Front panel LED power fault codes.
1
Facility power is not present, power cord is not attached, no power supplies are installed, or power supply failure has occurred.
2
If the health LED indicates a degraded or critical state, review the system Integrated Management Log (IML) or use HPE iLO to review
3
the system health status.
Subtopics
Subtopics
Server UID LED
Server UID LED
Using the UID button to view the Server Health Summary
Using the UID button to view the Server Health Summary
Front panel LED power fault codes
Front panel LED power fault codes
Server UID LED
Server UID LED
The UID LED is used to locate a particular server when it is deployed in a dense rack with other equipment. Activating the UID LED helps an
Status
Status
Solid green
1
Flashing green
Solid amber
Off
1
Solid green
Flashing green
Flashing amber
Flashing red
1
Solid green
Flashing green
Off
1
Solid blue
Flashing blue
Off
Definition
Definition
System on
Performing power-on sequence
System in standby
No power present
Normal
iLO is rebooting
System degraded
System critical
Linked to network
Network active
No network activity
Activated
1 flash per second—Remote management or
firmware upgrade in progress
4 flashes per second— iLO manual reboot
sequence initiated
8 flashes per second— iLO manual reboot
sequence in progress
Deactivated