Specification
Specification
Input requirements
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
HPE 1600 W Flex Slot -48 VDC Hot-plug Power Supply
HPE
1600 W Flex Slot -48 VDC Hot-plug Power Supply
Specification
Specification
Input requirements
Input requirements
Rated input voltage
Rated input frequency
Nominal input current
Maximum Rated Input Wattage Rating 1798 W at -40 VDC input
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
Value
Value
—
100 VAC to 127 VAC
200 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
11.3 A at 100 VAC
6.1 A at 200 VAC
1103 W at 100 VAC
1064 W at 200 VAC
3764 at 100 VAC
3629 at 200 VAC
—
1000 W at 100 VAC to 127 VAC
1000 W at 200 VAC to 240 VAC input
1000 W at 100 VAC to 127 VAC
1000 W at 200 VAC to 240 VAC
Value
Value
—
-40 VDC to -72 VDC
DC
45 A DC at -40 VDC input
36.6 A DC at -48 VDC input
24.4 A DC at -72 VDC input
1758 W at -48 VDC input
1755 W at -72 VDC input
6026 at -40 VDC input
6000 at -48 VDC input input
5989 at -72 VDC input
—
1600 W at -40 VDC to -72 VDC
1600 W at -40 VDC to -72 VDC
HPE ProLiant DL320 Gen11 Server Maintenance and Service Guide
260