Function List

This section lists the functions of IO-Link modules.
IO-Link master functions
Item
IO-Link cyclic transmission function
IO-Link transient communication
function
IO-Link device setting automatic
upload/download function
IO-Link device validation function
Disconnection detection function
Swap function
SIO mode function
Item
SIO input function
SIO output function
Number of SIO output ON times
integration function
CC-Link IE Field Network communication function
Item
Cyclic transmission
Transient transmission
Output HOLD/CLEAR setting function
CC-Link IE Field Network diagnostics
Description
Communicates process data periodically with the IO-Link device connected to
each channel.
Reads/writes parameters at any timing from/to the IO-Link device connected
to each channel.
Saves the parameter setting of the IO-Link device connected to each channel
in the IO-Link module, and as necessary, overwrites the parameter setting of
the IO-Link devices.
Use this function to inherit parameter setting of an IO-Link device when
replacing it.
This function validates compatibility and identity of the IO-Link device
connected to each channel. An error occurs if an IO-Link device is not
compatible or identifiable.
Detects disconnection if communication with an IO-Link device is lost in IO-
Link mode.
Swaps the upper and lower bytes of data sent and received between the IO-
Link module and the IO-Link device connected to each channel.
Description
The ON/OFF status of inputs is notified to Remote input (RX) of the CC-Link
IE Field Network.
The ON/OFF status of outputs is controlled with Remote output (RY) of the
CC-Link IE Field Network master station.
Counts the number of SIO output ON times of each channel.
Description
Periodically exchanges data among stations on the network using link
devices. An IO-Link module operates as an intelligent device station on the
CC-Link IE Field Network.
Reads or writes data on the IO-Link module in line with a dedicated instruction
from the master station.
This function sets the handling of the last output data when the IO-Link
module is disconnected from data link or when the CPU module is in the
STOP state, RESET state, or ERROR STOP state.
This function allows the presence or absence of a network error to be checked
by accessing the engineering tool connected to the CPU module.
Reference
Page 63 IO-Link cyclic transmission
function
Page 65 IO-Link transient
communication function
Page 66 IO-Link device setting
automatic upload/download function
Page 69 IO-Link device validation
function
Page 72 Disconnection detection
function
Page 73 Swap function
Reference
Page 75 SIO input function
Page 76 SIO output function
Page 77 Number of SIO output ON
times integration function
Reference
Page 82 Cyclic transmission
Page 83 Transient transmission
Page 93 Output HOLD/CLEAR
setting function
Page 95 CC-Link IE Field Network
diagnostics
2 SPECIFICATIONS
2.3 Function List