5.6.3. Connecting the AC power cables

Prerequisites:
Tools: wire cutter, wire stripper pliers, spanner (size 19), torque wrench (size 19).
Make sure that the main switch of the power supply group for the product
is set to the OFF position. Do a voltage check to make sure that the
electrical power is disconnected from the system. Secure against
resetting.
1.
Cut the wires of the AC power cable to the proper lengths to reach the connectors. Do not
make the wire routing neither too tight nor too loose.
2.
Strip 20 mm of the insulation from the ends of the wires (B).
3.
Attach wire end rings (A) at the end of the wires.
4.
Remove the nuts and washers (C) from the bolts (M12) of connector block (D).
5.
Insert the 3 wires (B) with the nuts and washers onto the bolts of connector block (D).
• From left to right:
L1 (brown),
L2 (black),
L3 (grey or black).
6.
Tighten the nuts (C) with a tightening torque of 30 Nm.
Document: v0.1 / Document No.: TBA | Date: XX-08-2021
Method of connecting the AC power cables
HVC-R 100/150 V2 E-Bus Charger Installation Guide
DANGER
Page 71 of 133