8. Technical specification

8.1. Electrical specification od a complete 107 kW system

AC Input Power Cabinet
Supply voltage
Input voltage range
Input frequency range
Maximum power dissipation
Power factor (cos ᵠ)
Standby power consumption
Efficiency
Maximum input current
Nominal input current
Earth Leakage Current Protection
Short Circuit Capacity
AC power connection
AC Input Dual Depot Charge Box
Supply voltage
Input voltage
Input frequency range
Nominal input current
Earth Leakage Current protection
DC output
Maximum output power
Output voltage range
Maximum output current
Document: v0.1 / Document No.: TBA | Date: XX-08-2021
HVC-R 100/150 V2 E-Bus Charger Installation Guide
3-phase, 400 V AC: PE, L1, L2, L3
400 V AC ± 10%
50 Hz ± 4%
117 kVA
≥ 0.95
< 60 W
94% and 96% in power spectrum between 20% and
100% of full power
174 A AC
170 A AC
AC 100 mA (RCD integrated in HVC100(S))
AC 30 mA (RCD integrated in HVC100(S))
25 kA
2
240 mm
(max)
1-phase: GND, L, N
230 V AC ± 10%
47 - 63 Hz ± 1%
2.17 A AC
AC 30 mA
107 kW
150 – 850 V DC
166 A DC
Page 119 of 133