ABB HVC-R 100/150 V2 Installation Manual page 79

E-bus charger
Table of Contents

Advertisement

A
Terminal block
B
Interlock cable
1.
Move the cable towards the terminal block (A).
2.
Strip 11 mm of the insulation from the ends of the White and Brown wires only!
3.
Crimp a ferrule onto the ends of the White and Brown wires.
4.
Ensure that the unused wires (green and yellow) are secured so that they cannot touch
metal parts.
5.
Loosen the connector screws.
6.
Insert the wires into the connectors, see table below:
Functional description
Interlock In
Interlock Out
Interlock GND
See also Appendix F Signal connection diagram.
7.
Tighten the connector screws with a tightening torque of 1.3 Nm.
Document: v0.1 / Document No.: TBA | Date: XX-08-2021
Location of required terminal blocks
Connector
X8-14
X8-7
X8-Shield (refer to the picture above)
HVC-R 100/150 V2 E-Bus Charger Installation Guide
Wire color
Brown
White
Shield
Page 79 of 133