Connecting The Interlock Cable From The Power Cabinet Or The Dual Depot Charge Box - ABB HVC-R 100/150 V2 Installation Manual

E-bus charger
Table of Contents

Advertisement

5.14.9.
Connecting the InterLock cable from the Power Cabinet or the
Dual Depot Charge Box
Prerequisites:
Tools: wire cutter, wire stripper pliers, screwdriver, ferrules, crimp pliers
Location of terminal blocks X3 and the preferred cable route.
Positions of terminal blocks X3 required for connection of InterLock.
1. Loosen and remove the cable gland's (#03) nut for the Interlock cable.
2. Slide the cable gland's nut over the Interlock cable.
3. Route the Interlock cable through gland #03 to the terminal blocks X3. Refer to the
figure above for the preferred cable route through the cable duct inside the cabinet.
4. Shorten the InterLock cable to the correct length – allowing to reach the terminal block
X3. Do not make the cable routing too tight, or too loose.
5. Tighten the nut of the gland to secure the InterLock cable.
6. Strip 11 mm of the insulation from the ends of the wires.
7. Tighten the shield of the Interlock cable into a thread and slide a shrink tubing over the
it.
8. Crimp ferrules to the ends of the wires.
9. Loosen the connector screws.
10. Insert the wires of the InterLock cable into the connectors of the terminal block X3.
Refer to the table below:
Document: v0.1 / Document No.: TBA | Date: XX-08-2021
HVC-R 100/150 V2 E-Bus Charger Installation Guide