Removing And Installing The Protection Cover - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
12.3 Specific data gearbox
12.3.12

Removing and installing the protection cover

The protection cover of the hollow shaft is delivered ready-fitted to the gearbox flange. Remove
the protection cover to install the output shaft.
The plastic protection cover of the hollow shaft is supplied loose as kit.
Figure 12-18
Procedure
Premounted protection cover
1. Loosen the screws
ring 
2. Mount the output shaft.
3. Use a suitable cleaning agent to clean the contact surface of the protection cover
gearbox.
4. Ensure that the flat seal or the O-ring 
5. Wet the screws 
6. Screw on the protection cover 
7. Protect all remaining bare areas with a suitable permanent anti-corrosive agent.
You have now installed the protection cover for operation.
Protection cover (supplied loose)
When using the plastic protection cover for gearbox F49, break the cover into the correct
shape first.
When using the plastic protection cover for other gearboxes, it is not necessary to break the
cover into the required shape; in this case, start with Point 2.
490
Bolt
Protection cover
Protection cover for hollow shaft
. Remove the protection cover 
.
with medium-strength adhesive, e.g. Loctite 243.
Flat seal / O-ring
Gearbox housing
is correctly seated.
.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
together with the flat gasket or O-
on the