Limiting the output of the technology controller
Number
p2290[0...n]
p2291
p2292
p2293
r2294
p2295
p2296[0...n]
p2297[0...n]
p2298[0...n]
p2299[0...n]
p2302
Adapting the actual value of the technology controller
Parameter
p2264[0...n]
p2265
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Name
BI: Technology controller limitation
enable
CO: Technology controller maxi‐
mum limiting [%]
CO: Technology controller mini‐
mum limiting [%]
Technology controller ramp-up/
ramp-down time [s]
CO: Technology controller output
signal [%]
CO: Technology controller output
scaling [%]
CI: Technology controller output
scaling
CI: Technology controller maxi‐
mum limiting signal source
CI: Technology controller mini‐
mum limiting signal source
CI: Technology controller limita‐
tion offset
Technology controller output sig‐
nal start value [%]
Description
CI: Technology controller actual
value
Technology controller actual value
filter time constant [s]
Advanced commissioning
7.19 PID technology controller
Factory setting
Sets the signal source to enable the technology
controller output.
The technology controller output is enabled with a
1 signal.
Factory setting: 1
Sets the maximum limit of the technology control‐
ler.
Factory setting: 100
Sets the minimum limit of the technology control‐
ler.
Factory setting: 0
Sets the ramping time for the output signal of the
technology controller.
Factory setting: 1
Display and connector output for the output signal
of the technology controller.
Sets the scaling for the output signal of the tech‐
nology controller.
Factory setting: 100
Sets the signal source for the scaling value of the
technology controller.
Factory setting: 2295
Sets the signal source for the maximum limiting of
the technology controller.
Factory setting: 1084
Sets the signal source for the minimum limiting of
the technology controller.
Factory setting: 1087
Sets the signal source for the offset of the output
limiting of the technology controller.
Factory setting: 0
Sets the start value for the output of the technology
controller.
Factory setting: 0
Setting
Sets the signal source for the actual value of the
technology controller.
Factory setting: 0
Sets the time constant for the actual value filter
(PT1) of the technology controller.
Factory setting: 0