Siemens SINAMICS G115D Operating Instructions Manual page 416

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data
11.1 Technical data of the G115D wall-mounted converter
Frame
size
FSA
FSB
FSC
Typical current consumption on 24 V DC power supply
G115D
wall-moun‐
ted con‐
verter
 
FSA
FSB
FSC
The typical current consumption does not include the consumption of connected sensors at DI 0 to DI 3
1)
from the unswitched 24 V power supply and the consumption of connected sensors/actors at DIO 24/
DIO 25 from the switched 24 V power supply.
2)
The typical current consumption does not include the consumption of connected sensors at DI 0 to DI 3
from the yellow cable and the consumption of connected sensors/actors at DIO 24/DIO 25 from the
black cable.
The current consumption for digital inputs DI 0 ~ DI 3 is max. 200 mA in total. The current consumption
3)
for digital inputs DI 24 and DI 25 (when DIO 24/DIO 25 is configured as DI) is max. 200 mA in total, and
the current consumption for digital outputs DO 24 and DO 25 (when DIO 24/DIO 25 is configured as DO)
is max. 500 mA in total.
Standby currents
G115D wall-mounted converter
Frame size
Rated power
FSA
0.37 kW to 1.5 kW
FSB
2.2 kW to 4 kW
FSC
5.5 kW to 7.5 kW
414
Rated pow‐
er (kW)
Glanded
variant
0.37 to 1.5
5.54 (12.19) 5.66 (12.44) 5.77 (12.70) •
2.2 to 3
7.12 (15.67) 7.24 (15.92) 7.35 (16.18)
4
7.52 (16.55) 7.64 (16.80) 7.74 (17.03)
5.5 to 7.5
7.85 (17.27) 7.97 (17.52) 8.08 (17.78)
Rated power
Typical current consumption
from the 24 V power supply, un‐
switched
PROFINET var‐
iant
0.37 kW to 1.5
290 mA
kW
2.2 kW to 3 kW
290 mA
4 kW
550 mA
5.5 kW to 7.5 kW 580 mA
Standby current (mA)
Mains power supply without 24 V DC power supply
380 V, 50 Hz 380 V, 60 Hz 400 V, 50 Hz 400 V, 60 Hz 480 V, 50 Hz 480 V, 60 Hz
136
163
172
207
255
306
Net weight (kg/lb.)
Glanded
Connector
variant with
variant
Q8/0 or M12
1) 3)
I/O variant
250 mA
250 mA
510 mA
540 mA
143
171
181
217
268
322
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Additional weight
Integrated repair switch:
+0.18 (0.4)
Integrated LRC panel: +0.15
(0.33)
Integrated 24 V PSU:
+0.55 (1.21)
Typical current consumption
from the AS-i cable
2) 3)
AS-i variant
Yellow cable
Black cable
90 mA
200 mA
90 mA
200 mA
90 mA
460 mA
90 mA
490 mA
171
206
217
261
321
386