Replace Bearings - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
12.3 Specific data gearbox
If, following agreement, the gearbox is filled at the factory with special lubricant for the
applications listed above, the lubricant is shown on the rating plate.
The oil quality must meet the gearbox lubricant requirements specified in the NT 7300 table.
The Siemens warranty is otherwise null and void. We recommend the use of one of these
gearbox lubricants. These gearbox oils are subject to constant testing and meet the specified
requirements. It is possible that the recommended oils are deleted or replaced by oils that
have been further developed at a later point in time. We recommend that you regularly
check as to whether the selected lubricating oil is still recommended by Siemens. Otherwise
change the product.
Table 12-46
Lubricant table
Operating range
Oil grade
designation according to
DIN 51502
Helical gearbox E / Z / D, parallel shaft gearbox F and bevel gearbox K
Standard
CLP ISO VG220
CLP ISO PAO VG220
CLP ISO PAO VG68
CLP ISO PG VG460
CLP ISO PG VG220
Food sector (USDA)
CLP ISO H1 VG460
NSF-H1
CLP ISO H1 VG100
Biodegradable oil
CLP ISO E VG220
Helical worm gearbox C, bevel gearbox B
Standard
CLP ISO PG VG220
CLP ISO PAO VG460
CLP ISO PAO VG220
CLP ISO PAO VG68
CLP ISO PG VG460
Food sector (USDA)
CLP ISO H1 VG460
NSF-H1
CLP ISO H1 VG100
CLP = mineral oil
CLP PG = polyglycol oil
E = ester oil, organic oil (bio oil / risk of water pollution, class WGK1)
PAO = poly-alpha-olefin oil
CLP H1 = physiologically safe oil (USDA-H1 approval)
12.3.25

Replace bearings

The bearing service life is finite, greatly depends on the operating conditions and therefore
cannot be calculated reliably. In the operating conditions specified by the operator, bearing life
can be calculated. Changes in vibration and noise pattern are an indication that an immediate
bearing replacement is necessary.
524
Permissible oil
Ambient temperature
sump tempera‐
°C
ture range dur‐
ing operation
°C
-15 ... +40° 
-15 ... +80°
-30 ... +100°
-40 ... +60°
-
-25 ... +110°
-25 ... +110°
-25 ... +100°
-30 ... +90°
-20 ... +100°
-20 ... +40° 
-25 ... +110°
-25 ... +110°
-30 ... +100°
-40 ... +60°
-
-25 ... +110°
-25 ... +100°
-30 ... +90°
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
-30 ... +40° 
-
-
-
-
-
-30 ... +40° 
-
-
-
-
-
SINAMICS G115D Wall Mounted distributed drive
-20 ...+55 
-
-
-20 ...+55 
-