Advanced commissioning
7.4 Controlling clockwise and counter-clockwise rotation via digital inputs
Changing the assignment of the digital inputs
Parameter
p3330[0 ... n] =
722.x
p3331[0 ... n] =
722.x
7.4.4

Three-wire control, method 1

The "Enable" command is a precondition for switching on the motor. Commands "ON
clockwise rotation" and "ON counter-clockwise rotation" switch on the motor - and
simultaneously select a direction of rotation. Removing the enable switches the motor off
(OFF1).
Enable / OFF1
Parameters
Select three-wire control, method 1
Parameter
p0015 = 63
140
Description
BI: 2/3 wire control command 1 (ON/OFF1 clockwise rotation)
BI: 2/3 wire control command 2 (ON/OFF1 counter-clockwise rotation)
Example: p3331 = 722.0 ⇒ DI 0: ON/OFF1 counter-clockwise rotation
ON clockwise ro‐
tation
0
0 or 1
1
0→1
1
0
1
1
Description
Macro drive unit
You must carry out quick commissioning in order to set parameter p0015.
Assigning digital inputs DI to the commands:
DI 0: Enable/OFF1
DI 1: ON counter-clockwise rotation
DI 2: ON clockwise rotation
ON counter-clock‐
Function
wise rotation
0 or 1
OFF1: The motor stops.
0
ON: Clockwise motor rotation.
0→1
ON: Counter-clockwise motor rotation.
1
OFF1: The motor stops.