Parameter
p2119[0 ... 19]
p2126[0 ... 19]
p2127[0 ... 19]
For more information about this function, see function diagram 8075 and parameter
description in the List Manual.
9.6

List of alarms and faults

Overview
A message comprises a letter followed by the relevant number.
The letters have the following meaning:
A . . . .
F . . . .
The expressions have the following meaning:
CU/Power Module/power unit
 
 
Important alarms and faults
Number
Cause
F01000
Software fault in CU
F01001
Floating Point Exception
F01015
Software fault in CU
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Description
Changing message type, type Sets the message type for the selected fault or
Changing the acknowledg‐
ment mode, fault number
Changing the acknowledg‐
ment mode
Alarm code . . . .
Fault code . . . .
All refer to an Electronic Module.
For example, replacing a CU, Power Module, or power unit
means replacing an Electronic Module.
Remedy
Replace CU.
Switch CU off and on again.
Upgrade firmware or contact technical support.
Alarms, faults and system messages
9.6 List of alarms and faults
Setting
alarm.
1: Fault
2: Alarm
3: No message
Factory setting: 1
Selects the faults for which the acknowledge mode
is to be changed.
Factory setting: 0
Sets the acknowledgment type for the selected
fault:
1: Acknowledgment only using POWER ON
2: Immediate acknowledgment after removing the
fault cause
Factory setting: 1