Technical data
11.1 Technical data of the G115D wall-mounted converter
Property
Earth fault current
Electromechanical (EM) brake
For IT system, only permissible when the functional grounding in the converter has been removed.
1)
Safety Integrated
Property
Safety function
 
Environmental conditions
Property
Surrounding tem‐
Storage
perature
Transport
Operation
Vibration and
Transport
shock
Operation
Resistance to biologically active sub‐
stances
Pollution degree
Relative humidity
412
Explanation
The converter can be operated with a type B 300 mA RCD.
180 V DC
– Rated current: 0.8 A
– Disconnection on the DC side permits "fast" braking
400 V AC (optional, for wall-mounted converter only)
– Rated current: 1 A
Explanation
STO and SLS
STO and SLS fulfil the requirements of the following standards:
SIL 2 according to IEC61508, part 1 to 3 (2010)
PL d according to IEC61800-5-2 (2016)
Category 3 according to ISO13849 part 1 (2015)
The function STO corresponds to stop category 0 according to IEC60204 (2005). STO
is always prioritized higher than SLS.
Response Time
The response times for the Safety Integrated functions can be found under:
Safety Integrated response times
view/109782490)
Probability of failures
The PFH values can be found under:
PFH values (https://support.industry.siemens.com/cs/ww/en/view/76254308)
Explanation
-40 °C to +70 °C, Class 1K4 according to IEC 60721-3-1, in product packaging
-40 °C to +70 °C, Class 2K4 according to IEC 60721-3-2, in transport packaging
-30 °C to +55 °C
, Class 3K3 according to IEC 60721-3-3
1)
Power derated by 3%/K when > 40 °C
Current derating as a function of the surrounding temperature (Page 419)
Class 2M3, test according to EN 60721-3-2
Class 3M2, test according to EN 60721-3-3
Class 3B1 according to EN 60721-3-3
Suitable for pollution degree 2 environment according to IEC 61800-5-1
< 95% (non-condensing, no icing, no salt spray)