Electromechanical Potentiometer - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Parameter
r1073
p1075[0...n]
p1076[0...n]
r1077
r2050[0...11] CO: PROFIdrive PZD receive word
Further information
For further information refer to the function diagrams 2468, 9360 and 3030 of the List Manual.
7.17.3

Electromechanical potentiometer

The converter has two electromechanical potentiometers.
The potentiometers are hardwired with the internal analog inputs 0 and 1.
For more information on using a tool to adjust the two electromechanical potentiometers,
refer to the replacing procedure in Section "Replacing the Electronic Module (Page 394)".
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Description
CO: Main setpoint active
CI: Supplementary setpoint
CI: Supplementary setpoint scaling Signal source for scaling the supplementary set‐
CO: Supplementary setpoint effec‐
tive
Advanced commissioning
Setting
Displays the active main setpoint.
Signal source for the supplementary setpoint.
Factory setting: 0
point. Factory setting: 0
Displays the effective supplementary setpoint.
Connector output to interconnect the PZD received
from the fieldbus controller in the word format.
[1] Most standard telegrams receive the speed set‐
point as receive word PZD02.
7.17 Setpoints
257