Advanced commissioning
7.6 Drive control via Ethernet/IP
Class Attribute
No.
1
2
3
Instance Attribute
No.
2
3
6
7
8
9
10
11
12
13
14
15
19
TCP/IP Interface Object, Instance Number: F5 hex
Supported services
Class
Class Attribute
No.
1
2
3
Instance Attribute
No.
1
2
168
Service
Type
get
UINT16
get
UINT16
get
UINT16
Service
Type
Name
get, set
UINT16
Commissioning state
get
INT16
Motor Type
get, set
REAL
Rated Current
get, set
REAL
Rated Voltage
get, set
REAL
Rated Power
get, set
REAL
Rated Frequency
get, set
REAL
Rated Temperature
get, set
REAL
Max Speed
get, set
UINT16
Pole pair number
get
UINT32
Torque Constant
get, set
REAL
Inertia
get, set
REAL
Base Speed
get, set
REAL
Cos Phi
• Get Attribute all
• Get Attribute single
Service
Type
get
UINT16
get
UINT16
get
UINT16
Service
Type
Name
get
UNIT32
Status
get
UNIT32
Configura‐
tion Capabil‐
ity
Name
Revision
Max Instance
Num of Instances
Value/explanation
p0010
p0300
p0305
p0304
p0307
p0310
p0605
p0322
p0314
p0316
p0341
p0311
p0308
Instance
Name
Revision
Max Instance
Num of Instances
Value/explanation
Fixed value: 1 hex
1:  Configuration acknowledged, by DHCP or saved values
Fixed value: 94 hex
4 hex:  DHCP supported,
10 hex:  Configuration can be adjusted,
80 hex:  ACD-capable
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
• Get Attribute all
• Get Attribute single
• Set Attribute single