Additional information on the SIMOGEAR geared motor
12.1 General information geared motor with SINAMICS G115D Motor Mounted / Wall Mounted
NOTICE
Overheating caused by solar radiation
Overheating of the geared motor due to exposure to direct sunlight.
Provide suitable protective equipment such as covers or roofs. Prevent heat accumulation.
NOTICE
Malfunction resulting from foreign objects
The operator must ensure that no foreign objects impair the function of the gearbox.
NOTICE
Damaged components impair the correct function of the gearbox
If any components are damaged, the correct function of the gearbox will no longer be ensured.
Do not install any damaged gearbox components.
NOTICE
Violation of the maximum permissible oil sump temperature
The oil sump temperature will be exceeded if the temperature monitoring equipment is
incorrectly set.
An alarm must be output when the maximum permissible oil sump temperature is reached. The
geared motor must be switched off when the maximum permissible temperature is exceeded.
The machine will come to a standstill if the geared motor is shut down.
Note
Use headless screws with property class 8.8 or higher to fasten the motor.
Exercise particular care during mounting and installation. The manufacturer cannot be held
liable for damage caused by incorrect mounting and installation.
Make sure that there is sufficient space around the gearbox or geared motor for mounting,
maintenance and repair.
On geared motors with a fan, leave sufficient free space for air to enter. Observe the
installation conditions for the geared motor.
Provide adequate lifting gear at the start of mounting and installation work.
Observe the mounting position specified on the rating plate. This ensures that it will be
provided with the correct quantity of lubricant.
Use all the fastening means that have been assigned to the particular mounting position and
mounting type.
Cap bolts cannot be used in some cases due to a lack of space. In such cases, please contact
Technical Support, specifying the type of gearbox.