Removing and installing the protection cover

The protection cover of the hollow shaft is delivered ready-fitted to the gearbox flange.
Remove the protection cover to install the output shaft.
The plastic protection cover of the hollow shaft is supplied loose as kit.
Figure 11-18 Protection cover for hollow shaft
Procedure
Premounted protection cover
1. Release the screws ① and remove the protection cover ② together with the flat gasket or O-
ring ③.
2. Mount the output shaft.
3. Use a suitable cleaning agent to clean the contact surface of the protection cover ② on the
gearbox.
4. Ensure that the flat seal or the O-ring ③ is correctly seated.
5. Apply medium-strength adhesive, e.g. Loctite 243 to the screws ①.
6. Screw on the protection cover ②.
7. Protect all remaining bare areas with a suitable permanent anti-corrosive agent.
You have now installed the protection cover for operation.
Protection cover (supplied loose)
When using the plastic protection cover for gearbox F49, the cover must first be brought into
the correct shape.
When using the plastic protection cover for other gearboxes, it is not necessary to bring the
cover into the required shape; in this case, start with Point 2.
448
Bolt
Protection cover
Flat seal / O-ring
Gearbox housing
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
SINAMICS G115D distributed drive