Advanced commissioning
7.9 Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
Note
The motor will have the following behavior with the end position shutdown (p3392 = 1) and
level-triggered sensor signals (p3394 = 1 or 2) activated:
• Once a stop sensor at the positive or negative position is triggered, the motor stops even if
the level is canceled.
• Once a stop sensor at the center position is triggered, the motor stops; if the level is cancelled,
then the motor runs again.
Parameters
204
Conveyor technology control parameters (Page 220)
SINAMICS G115D Wall Mounted distributed drive