Siemens SINAMICS G115D Operating Instructions Manual page 161

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Parameter
p8982
p8983
For more information about the parameters, refer to the List Manual.
Further information
Ethernet/IP objects and assemblies of the converter:
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Description
Ethernet/IP ODVA speed scaling
Ethernet/IP ODVA torque scaling
Overview of the manuals (Page 588)
Supported objects (Page 160)
Advanced commissioning
7.6 Drive control via Ethernet/IP
Setting
Sets the scaling for the speed for Ethernet/IP ODVA
profile (p8980 = 1).
123: Scaling = 32
124: Scaling = 16
125: Scaling = 8
126: Scaling = 4
127: Scaling = 2
128: Scaling = 1 (factory setting)
129: Scaling = 0.5
130: Scaling = 0.25
131: Scaling = 0.125
132: Scaling = 0.0625
133: Scaling = 0.03125
Sets the scaling for the torque for Ethernet/IP ODVA
profile (p8980 = 1).
123: Scaling = 32
124: Scaling = 16
125: Scaling = 8
126: Scaling = 4
127: Scaling = 2
128: Scaling = 1 (factory setting)
129: Scaling = 0.5
130: Scaling = 0.25
131: Scaling = 0.125
132: Scaling = 0.0625
133: Scaling = 0.03125