Figure 8.16 Virtual Keypad For Hex Data Bit - Rigol MSO8000A Series User Manual

Digital oscilloscope
Hide thumbs Also See for MSO8000A Series:
Table of Contents

Advertisement

-
-
A&D: the oscilloscope searches for the specified address and data at the same
time, then triggers when both the address and data meet the conditions. After
this condition is selected, you need to set the sub-menu items such as Bit X,
Bytes, Addr Bits, Address, and Direction. For the setting methods, refer to
descriptions in "Address" and "Data" conditions.
Trigger Mode:
In the trigger control area (Trigger) on the front panel, press
the current trigger mode. For details, refer to descriptions in "
Trigger Parameter Setting:
Sets the trigger parameter (noise rejection) under this trigger type. For details, refer
to descriptions in "
Trigger LEVEL/Threshold Level:
Rotate the Trigger
refer to descriptions in "
threshold level is displayed at the upper-right corner of the screen.
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Figure 8.16 Virtual Keypad for Hex Data Bit

Press Bytes, then rotate the multifunction knob
numeric keypad to set the length of the data. Its range is from 1 to 5.
Press More > Addr Bits, then rotate the multifunction knob
the desired address bits, and then press down the knob to select it. You can
also press Addr Bits continuously or enable the touch screen to select it.
The available address bits are "7 Bits", "8 Bits", and "10 Bits".
Noise Rejection
LEVEL knob to adjust the trigger level/ threshold level. Please
Trigger LEVEL/Threshold Level
".
". The current trigger level/
To Trigger the Oscilloscope
or use the pop-up
to select
to quickly switch
Trigger Mode
".
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mso8074aMso8154aMso8204a

Table of Contents