9.12 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-IPGW
9.12 PBX Configuration—[1-1] Configuration—Slot
—Port Property—V-IPGW
Various settings can be programmed for each virtual IP Gateway port.
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Trunk Adaptor
To connect to a Trunk Adaptor, follow the steps below.
1.
Ensure that the Trunk Adaptor is connected to the network and a power supply.
2.
Click Trunk Adaptor. The Trunk Adaptor List screen is displayed.
3.
Enter a name (20 characters or less) for the Trunk Adaptor in Trunk Adaptor Name.
4.
Enter the Trunk Adaptor's IP address in Trunk Adaptor IP Address.
5.
To confirm that the setting is correct, click Connect. If the setting is correct, the Trunk Adaptor's Web
Maintenance Console will open in a new browser window.
For details about the Trunk Adaptor's Web Maintenance Console, refer to the documentation of the
Trunk Adaptor.
6.
Click OK.
Name
Connection
Connection
Attribute
Call
Distribution
Port Group
Ringback Tone
to Outside
Caller
224
PC Programming Manual
Description
Indicates the port status. To change the
status of the port, click the desired cell
in the column, and then select INS or
OUS for the port.
This option is only available in On-line
mode.
Specifies whether to connect a port to a
Trunk Adaptor or use it as an IP
gateway.
Specifies a call distribution port group
to which incoming trunk calls are
directed through the virtual VoIP
gateway port.
Enables the PBX to send a ringback
tone to an outside caller when the
network cannot send the tone.
Value Range
INS: The port is in
service.
OUS: The port is out of
service.
Fault: The port is not
communicating with the
network.
Gateway, Trunk
Adaptor
1–48
Disable, Enable
Links
Feature Manual
References
5.3.1 Trunk
Adaptor
Connection
Feature Manual
References
4.3.2.3 Call
Distribution Port
Group