Panasonic KX-NS300 Pc Programming Manual page 113

Hybrid ip-pbx
Hide thumbs Also See for KX-NS300:
Table of Contents

Advertisement

Item
Index
Shelf
Slot
Port
Connection
LAN Sync Status
LAN Sync Quality Level
To monitor the status of CSs
1.
From the LAN Synchronisation Group Number drop-down list, select the desired LAN
Synchronisation Group number.
2.
From the Interval Timer drop-down list, select the number of seconds between each automatic screen
refresh.
3.
Click Start to monitor the status of LAN synchronisation.
Monitoring will be performed and the screen will refresh according to the specified interval.
4.
Click Stop to end monitoring.
5.
To refresh the screen manually at any time, click Refresh.
6.
To collect the monitored data, click Start Capture.
7.
Click Stop Capture to finish and save the monitored data.
A dialogue box will be displayed.
8.
Navigate to the folder in which you want to save the file.
9.
Enter a file name.
10.
Click Save.
The dialogue box will close.
7.4.5 Utility—Monitor/Trace—CS Status Monitor—LAN Sync Group
Description
A unique index for the CS. (This depends on the number of V-IPCS4
cards and the number of connected CSs.)
Always displays "Virtual".
The slot number of the CS in the selected synchronisation group.
The port number of the CS.
The connection status of the CS (OUS/INS/Fault).
The current synchronisation status of the CS, as follows:
1.
No Sync.: Attempting to establish synchronisation
2.
Establishing Sync.: Establishing synchronisation
3.
Good: Currently synchronised
4.
Keep Sync.: Maintaining synchronisation
5.
Unstable: The CS is running unsynchronised
6.
Sync. Lost: Synchronisation has been lost
7.
Out of system: Cannot communicate with the PBX
8.
Sync. Master: CS is the sync master or is a slave acting as the sync
master
Shows the quality of the synchronisation, depending on the value of LAN
Sync Status, as follows:
1, 7, 8: "–" is displayed.
6: The quality of the synchronisation before synchronisation was lost is
displayed.
Other: A number indicating the quality of the synchronisation (-16384–
16384 ns).
PC Programming Manual
113

Advertisement

Table of Contents
loading