Canon imageRUNNER ADVANCE C5255 Series Service Manual page 215

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

2
Technology > MEAP > Maintenance > Procedures to Restore Backup Data
CAUTION:
Do not execute [Initialize All Data/Settings] in user mode during the period from backup
using SST to recovery of the data.
When [Initialize All Data/Settings] is executed, the key used to decrypt encrypted
backup data (SMS password, etc.) is initialized, which makes it impossible to decrypt
the data.
It means that SMS cannot be accessed even when the backup data has been
recovered using SST.
If you inadvertently executed [Initialize All Data/Settings] and can no longer access
SMS, the SMS login password needs to be initialized by following the procedure shown
in "When SMS Cannot Be Accessed" in "Login to SMS" in this manual.
2
Technology > MEAP > Maintenance > Procedures to Restore Backup Data
■ Procedures to Restore Backup Data
1) Connecting to the device
2) Restoring backup file
F-2-302
3) Transferring Data
4) Turn off and on the main power switch of the device to gain access in SMS to check that
5) Restore the backup data and setting saved. Note that the user information of the local
Connect the device using SST by following step 1 to step 4 of the Procedure for backing up
the MEAP application area using SST.
Click [Download Data] button and select the data backed up in the previous step (Meapback.
bin) to click [Start Restoring Data]. Note that the data backed up in a different version
cannot be restored.
When the data is successfully transferred, click the [OK] button shown on the screen. To
continue other jobs, click [Return to Menu] button.
MEAP applications are surely restored.
device is included in the backup data, thus does not need to be restored.
2-177