Contact Closure Programming
Setting up a General Purpose Contact Closure Input for
Time Clock Mode Control
Either CCI 1 or CCI 2 can be programmed to control the mode of the Time Clock (Home or Away). Follow the
procedure below to program a closure to control the Time Clock Mode.
Step 1
Go to Contact Closure Setup
Main Menu
Contact Closure Setup
From Contact Closure Setup, select either
CCI 1 or CCI 2.
Step 2
Setup Contact Closure Type
CCI 2 Setup
Set Type - - -
Clock Mode
Closure Settings
Test CCI
Back
Use
and
to set the type to Clock Mode.
Note: Only one CCI can be set to control the
mode of the Time Clock.
Step 3
Setup Closure Settings
From CCI 1 (or CCI 2) Setup, select Closure
Settings.
Closure Settings
When the CCI is closed,
the home owner is
Away
Cancel
Use
and
to select whether a closure of
the CCI indicates Home or Away. Press
"Done" (
button) to accept the setting.
• The CCI is now set up for Time Clock
Mode Control.
76
Setup Guide for the RadioRA Chronos System Bridge
Help
Done