Returning Components to Default Factory Settings
RS-232 Interface
Returning an RS-232 Interface to Default Factory Settings will permanently delete all current program-
ming information. Do not do this unless you are sure that it is necessary. For more information call
the Lutron Technical Support Center.
Step 1
Begin Returning to Default
Factory Settings
Ensure that the Chronos
in Activate Controls Mode, or the ACTIVATE
REPEATER LED or ACTIVATE CONTROLS
LED on any Repeater is NOT ON before pro-
ceeding. If either LED is ON, press the corre-
sponding button until it's LED turns OFF
(approximately 3 seconds).
Press and hold the Up and Assign buttons
until the display turns OFF and the LEDs
begin to flutter (approximately 3 seconds).
LEDs will flash for only 3 seconds.
100
Setup Guide for the RadioRA Chronos System Bridge
System Bridge is not
TM
Step 2
Return to Default Factory
Settings
While the LEDs are fluttering, press and hold
the Down and Level Set buttons until the
Interface resets ("– –" will be on the display).
All LEDs (except the Power LED) will turn
OFF and the display will show "– –" indicating
that the Interface has been returned to Default
Factory Settings.